● Extended bonnet design to ensure reliability of the stem packing & sealing.
● Drainage board design to prevent condensation water.
● Anti-Statistic & Fire-safe Design.
● Cavity automatic self pressure relief, suitable and safe for explosive medium.
● Live-load API 622 certified graphite and lip-seal sealing to ensure API 624 fugitive emission compliance.
● Suitable for working temperature as low as -196℃ .
● Multiple Seat Design option, suitable for various working medium and condition.
● Top Entry or Side Entry optional design.
◎ Material: Stainless Steel, Alloy Steel
◎ Nominal Size: NPS 1/2"~24", DN 15~600
◎ Pressure Rate: Class 150~2500, PN 10~420
◎ Temperature Range: -196°C~+150°C
◎ Operator: Manual, Pneumatic, Electric, etc...
◎ Application Range: LNG, LPG, LNG low temperature conditions and long-distance pipelines such as oil, gas, and natural gas.
The General Cast Steel Gate Valve is mainly composed of valve body, valve cover, valve wedge, valve seat and valve stem. The two sealing surfaces are wedge-shaped gate valves. The purpose of the wedge is to improve the auxiliary seal load, to achieve both high medium pressure sealing and low medium pressure sealing. The valve body of the wedge valve is provided with a guide mechanism, which can prevent the gate from rotating when the gate is turned on or closed, ensuring that the seal of the gate on the valve seat is accurate accordingly. At the same time, the wedge valve does not rub with the valve seat before turning off, thereby reducing the wear of the cover and effectively extending the service life of the valve.
RAYS Top Entry Cryogenic C-Type Ball Valve is a specially designed ball valve suitable for ultra-low temperature environments, especially for the control of cryogenic fluid media such as liquefied natural gas (LNG), liquid oxygen, and liquid nitrogen. The characteristic of the top entry C-Type C-Type ball valve lies in its special structural design.
The “Double Block and Bleed Isolation Philosophy” requires two in-line isolation valves and a bleed valve, used to drain or vent trapped fluid between the two closure elements in order to safely isolate safely the downstream pipe. This feature can be achieved with one single valves c/w a bleed port between the obturators.