● Side-entry design: Facilitates maintenance and installation in compact spaces.
● Bolted body construction: Enhances structural stability for safety in high-pressure applications.
● Anti-blowout stem design: Increases operational safety by preventing stem dislocation under extreme pressures.
● Double block and bleed system: Provides dual safety and effectively prevents leaks.
● Automatic cavity relief: Automatically regulates internal pressure to prevent accidental overpressure.
● Metal-to-metal seating: Ensures seal integrity and durability in high-temperature and corrosive environments.
● Hypersonic spraying technology: Surface strengthening for improved wear and corrosion resistance.
● Bond strength of 210,000 psi: Ensures stability and sealing under extremely high pressures.
● Anti-coking and self-cleaning design: Reduces maintenance needs and extends service life.
◎ Material: Carbon Steel, Stainless Steel, Alloy Steel
◎ Nominal Size: NPS 2" ~10", DN 50~250
◎ Pressure Rate: Class 150~2500, PN 10~420
◎ Temperature Range: -46°C~+538°C
◎ Operator: Manual, Pneumatic, Electric, etc...
◎ Application range: petroleum, chemical industry, metallurgy, light industry, power station, urban construction water supply, low temperature working conditions, and long-distance pipelines such as oil, gas, and natural transportation.
The “Double Block and Bleed Isolation Philosophy” requires two in-line isolation valves and a bleed valve, used to drain or vent trapped fluid between the two closure elements in order to safely isolate safely the downstream pipe. This feature can be achieved with one single valves c/w a bleed port between the obturators.
The Non-Rising Stem Gate Valve is also called the rotating stem gate valve. Stem and nut are arranged on the gate plate, handwheel rotation drive valve stem rotate to lift the gate, usually there is a trapezoidal thread at the bottom of the valve stem and the rotation movement is turned into a linear motion through the limit slot between the valve stem and the gate body and the gate body and the gate, that is, the operation torque is turned into operation thrust. When the valve is turned on, when the height of the gate is equal to the diameter of the valve 1: 1: 1, the channel of the fluid is completely unblocked, but at the run, this position cannot be monitored. In actual use, the vertex of the valve stem is used as a sign, that is, the position that is unmoved as its full opening position. The non-rising stem gate valve has the design characteristics of the ordinary wedge-type gate valve. The valve body has a guide mechanism, which can prevent the gate from rotating when the gate is turned on or closed, ensuring that the seal of the gate on the valve seat is accurate accordingly. At the same time, the wedge valve does not rub with the valve seat before turning off, thereby reducing the wear of the cover and effectively extending the service life of the valve.
C700 Series Single Seated Control Valve is a top-guided structure control valve, used in equipment that can achieve air opening or air closing. The fluid channel of the valve body is in an S-shaped streamlined shape, featuring low pressure drop loss, large flow rate, wide adjustable range, high accuracy of the flow characteristic curve, large guiding area of the valve core, and good vibration resistance. The control valve is equipped with a multi-spring diaphragm actuator, which features a compact structure and large output force. It can be used to control various fluids with different pressures and temperatures.